Follow us :

GFL-Y02IU-485-N Laser measurement distance|Laser Ranging Sensor|DADISICK

GFL-Y02IU-485-N Laser measurement distance|Laser Ranging Sensor|DADISICK
GFL-Y02IU-485-N Laser measurement distance|Laser Ranging Sensor|DADISICKGFL-Y02IU-485-N Laser measurement distance|Laser Ranging Sensor|DADISICKGFL-Y02IU-485-N Laser measurement distance|Laser Ranging Sensor|DADISICKGFL-Y02IU-485-N Laser measurement distance|Laser Ranging Sensor|DADISICKGFL-Y02IU-485-N Laser measurement distance|Laser Ranging Sensor|DADISICK
group name
GFL-Y Series
Min Order
1 piece
brand name
DADISICK
model
GFL-Y Series|GFL-Y02IU-485-N
Delivery clauses under the trade mode
CIP
update time
Thu, 21 Nov 2024 21:16:13 GMT

Paramtents

  • Output method: NPN+analog+RS485

  • Resolution: 1mm

  • Laser type: Red semiconductor laser Class II laser 655+10nm<1m

  • Voltage: 12V-24V DC

  • Current consumption: ≤50mA

  • Reaction time: 50-200ms

Packging & Delivery

  • Min Order1 piece

Briefing

Output method: NPN+analog+RS485
Resolution: 1mm
Laser type: red semiconductor laser Class II laser 655+10nm1m
Reaction time: 50-200ms
Measure distance: 0.1-2m

Detailed

GFL-Y series laser ranging sensor models comparison
Item
Model
NPN+analog+RS485
GFL-Y01IU-485-N
GFL-Y02IU-485-N
GFL-Y05IU-485-N
PNP+analog+RS485
GFL-Y01IU-485-P
GFL-Y02IU-485-P
GFL-Y05IU-485-P
Measure distance
0.1-1m
0.1-2m
0.1-5m
Models comparison
Item
Model
NPN+analog+RS485
GFL-Y10IU-485-N
GFL-Y20IU-485-N
GFL-Y50IU-485-N
PNP+analog+RS485
GFL-Y10IU-485-P
GFL-Y20IU-485-P
GFL-Y50IU-485-P
Measure distance
0.1-10m
0.1-20m
0.1-50m
Technical Parameters
Resolution
1mm
Measurement error
+(2mm+d*1/10,000)★
Laser type
Red semiconductor laser Class II laser 655+10nm<1mW
Voltage
12V-24VDC+10% pulsation P-P10%
Current consumption
≤50mA @24V
Control output
NPN or PNP open drain output
Open drain collector transistor output
Maximum current:50mA
Applied voltage: less than 30V DC
Residual voltage: less than 1.5V
Leakage current: less than 0.1mA
Output action
Normally open/normally closed can be switched
Short circuit protection
Automatic recovery type
Analog voltage output
Output range: 0-5V (alarm: 5.2V) Output impedance: 100Ω
Analog current output
Output range: 4-20mA (alarm: 0mA) Output impedance: 300Ω max
Reaction time
50-200ms
External input
NPN contactless input
Protective structure
IP67
Operating temperature
-10C~+45℃ (be careful not to condense or freeze)
Storage temperature
-20℃~+60℃
Working humidity
35%~85%RH
Use ambient illumination
Incandescent lamp: light receiving surface illumination below 3000lux
Use elevation
Below 2000m
Cable
With 8-core composite cable 2m
Material
Aluminum parts
Quality
About 150g
★: Indicates the measurement distance. In harsh environments, such as when the sunlight is too strong, the ambient temperature fluctuates too much, and the reflective surface is dark, the measurement results will have larger errors. In this case, the use of a target reflective plate will be better.
DIMENSION                                                                                                                                                                                                  
GFL-Y series Laser Ranging Sensor dimension
WIRING DIAGRAM                                                                                                                                                                                    
NPN/PNP switch output Wiring Method
GFL-Y series Laser Ranging Sensor NPN/PNP switch output Wiring Method
RS485 Wiring Method
GFL-Y series Laser Ranging Sensor RS485 Wiring diagram
DOCUMENTS & DOWNLOADS                                                                                                                                                                  
CATALOGUE

GFL-Y series Laser Ranging Sensor
User manual for GFL-Y series laser ranging sensors