  • A: Each DADISICK security product comes with a detailed installation and use manual, and provides a matching video tutorial to help you quickly master the installation process. If you have any questions, we also provide remote technical support to assist you in successfully completing the installation. Therefore, most users can easily complete the installation without worrying about complicated op...

  • A:Safety light curtains are often used in the following areas that require personnel protection:1. Hazardous areas of mechanical equipmentSuch as the feed port or operation area of ​​equipment with moving parts such as punching machines, shearing machines, injection molding machines, bending machines, etc.2. Both sides of the conveyor belt of the automated production linePrevent personnel from acc...

  • A:The installation distance and response time of the proximity switch should be determined according to the following factors:✅ Installation distance (detection distance)· Material of the object to be detected: Metal materials (such as iron and steel) are best for inductive proximity switches; non-metallic objects require capacitive proximity switches.· Switch type:-Shielded type: Installed flush ...

  • The installation steps of the safety touch edge are briefly as follows:1. Confirm the installation location: select the edge that needs to be protected, such as automatic doors, lifting platforms, robotic arms, etc.2. Fix the bracket or rail: fix the touch edge on the surface of the equipment or in the matching aluminum profile groove to ensure that the installation is straight and firm.3. Avoid e...

  • A:Safety relays can be used as central control modules to integrate multiple safety input devices (such as emergency stop buttons and safety light curtains) into a safety loop. The connection method is as follows:1. Emergency stop button connection:Connect the normally closed contact of the button to the input of the safety relay. When the button is pressed, the contact is disconnected, the relay ...

  • A:The installation of ultrasonic sensors must comply with the following requirements to ensure their measurement accuracy and stability:Reasonable installation positionThe sensor should be aligned vertically with the target surface to avoid large angle deviations to ensure that the sound waves are correctly reflected and returned.Avoid interferenceThere should be no obstructions in front of the se...

  • A:After installing a new light curtain, the following tests should be performed to ensure that it operates properly and meets safety requirements:1. Light curtain alignment test: Confirm that the transmitter and receiver are correctly aligned and the beam is not blocked.2. Function test: Block the beam with an object to check whether the alarm or shutdown can be triggered correctly.3. Response tim...

  • A:1. Ambient temperature fluctuationsImpact: Temperature will change the speed of sound, which will affect the ranging accuracy.2. Strong wind interferenceImpact: Wind will disrupt the ultrasonic propagation path, resulting in unstable measurement.3. Rain, snow and humid environmentImpact: Water droplets may adhere to the surface of the probe or interfere with the propagation of sound waves.4. Dir...