Search This Supplers Products:Safety Light CurtainsMeasuring Light CurtainsLaser Scanning RadarSafety RelaysLaser Distance SensorSafety Mats
                                        




Paramtents
Response time: Up to 1.5ms
Output type Analog
Measuring center distance 400mm
Measuring range ±200mm
Repeatability 400μm(Range: 200~400mm)/800μm(Range: 400~600mm)
Supply voltage 12~24V DC±10%, pulsation P-P10%
Packging & Delivery
Min Order1 piece
Briefing
Detailed
| 
                                             Laser Ranging Sensor Measuring range specification 
                                         | 
                                        
                                        
                                        
                                    ||||||
Species  | Measuring  center 30mm  | Measuring  center 50mm  | Measuring  center 100mm  | Measuring  center 200mm  | Measuring center type 400mm  | |
Model  | NPN output  | GFL-Z50N  | GFL-Z100N  | GFL-Z200N  | GFL-Z400N  | |
Analog quantity output  | GFL-Z30NM  | GFL-Z50NM  | GFL-Z100NM  | GFL-Z200NM  | GFL-Z400NM  | |
RS485 communication  | GFL-Z30N-RS485  | GFL-Z50N-RS485  | GFL-Z100N-RS485  | GFL-Z200N-RS485  | GFL-Z400N-RS485  | |
Measuring center distance  | 
                                        30mm  | 50mm  | 100mm  | 200mm  | 400mm  | 
                                        
                                        
                                    |
Measuring range  | ±5mm  | ±15mm  | ±35mm  | ±80mm  | ±200mm  | 
                                        
                                        
                                    |
Repeatability  | 10μm  | 30μm  | 70μm  | 200μm  | 400μm(Measuring distance200~400mm) 800μm(Measuring distance400~600mm)  | |
Straightness  | ±0.1%F.S.  | ±0.2%F.S.  | ±0.2%F.S.(Measuring distance200~400mm) ±0.2%F.S.(Measuring distance400~600mm)  | |||
Temperature characteristic  | 0.03%F.S./℃  | |||||
illuminant  | Red semiconductor laser Class 2 Maximum output :1mW, light beam  wavelength :655nm  | |||||
Beam diameter  | About φ50μm  | About φ70μm  | Aboutφ120μm   | About φ300μm  | About φ500μm  | |
Supply voltage  | 12~24V DC±10%, pulsation P-P10%  | |||||
Current consumption  | Below 40mA (24V DC supply voltage), below 60mA (12VDC supply voltage)  | |||||
Control output  | <NPN output type > NPN open collector transistor ●Maximum inow current :50mA ●Applied voltage :30V DC below (control output -0∨) ●Residual voltage: less than 1.5V (inow current 50mA) ●Leakage current: below 0.1mA  | |||||
Output action  | ON in light/ON in non-light can be switched  | |||||
Short circuit protection  | Equipped (automatic recove type)  | |||||
Analogoutput  | Voltage analog output (When alert :+5.2V)  | Output range :0 to 5V Output impedance100Ω  | -  | Output range:0~5V Output impedance: 100Ω  | -  | Output range:0~5V Output impedance: 100Ω  | 
Current analog output (Ale :0mA)  | Output range :4 to 20mA Load impedance :300Ω or less  | -  | Output range :4 to 20mA Load impedance :300Ω or less  | -  | Output range :4 to 20mA Load impedance :300Ω or less  | |
| 
                                             Mechanical parameters 
                                         | 
                                        
                                        
                                        
                                    ||
| 
                                             Reaction time 
                                         | 
                                        1.5ms/5ms/10ms can be switched  | 
                                        
                                        
                                    |
| 
                                             External input 
                                         | 
                                        NPN No contact input Valid :0V to +12V DC Input impedance: about 10 kΩ  | 
                                        
                                        
                                    |
| 
                                             Protective construction 
                                         | 
                                        IP60  | 
                                        
                                        
                                    |
Degree of fouling  | 
                                        2  | 
                                        
                                        
                                    |
Operating ambient temperature  | -10℃~+40℃(pay attention to do not condensation, icing), storage :-20℃~+60°C  | |
Ambient humidity  | 35%~85%RH, storage :35%~85%RH  | |
Use ambient light  | Incandescent lamp: the illumination degree of the illuminated suace is less than 3000lx  | |
Service level  | Below 2000m  | |
Cable  | With 0.15mm 5-core composite cable 2m  | |
Material  | Body shell: aluminum casting front cover plate: propylene base  | |
weight  | Approx. 35g(without cable), Approx. 85g(with cable)  | |
Applicable specification  | Compliance with EMC directive  | |
(Note): When the measurement conditions are not specied, the use conditions are as follows: power supply voltage :24V DC,  ambient temperature :+20℃, reaction time :10ms, analog output value of the measurement center distance. Object Object: White paper.  | ||



网络文化经营许可证:浙网文[2013]0268-027号|增值电信业务经营许可证:浙B2-20080224-1 2007-2025 Tradevv.com. All rights reserved.