Follow us :

OX-D2-CO | Safety Switch | DADISICK

OX-D2-CO | Safety Switch | DADISICK
OX-D2-CO | Safety Switch | DADISICKOX-D2-CO | Safety Switch | DADISICKOX-D2-CO | Safety Switch | DADISICKOX-D2-CO | Safety Switch | DADISICKOX-D2-CO | Safety Switch | DADISICK
group name
OX-D2/OX-D3 Series
Min Order
1 piece
brand name
DADISICK
model
OX-D2 & OX-D3 | OX-D2-CO
Delivery clauses under the trade mode
CIP
update time
Thu, 21 Nov 2024 20:55:54 GMT

Paramtents

  • Full range of gold-plated contacts: Configure 5 contact structures

  • Suitable for standard and small loads: Adjust up to 8 directional key operation holes

  • Certification: GB14048.5-2017, IEC/EN60947-5-1

  • Contact type: 1NC+1NO

Packging & Delivery

  • Min Order1 piece

Briefing

Used for monitoring places such as safety doors and windows.

Detailed

Safety Switch Performance Specifications
Applicable standard
IEC/EN60947-5-1/GB14048.5-2017
Protection level*1
IP65/IP67 (EN60947-5-1 key operation hole)
Service life*2
More than 1 million machinery/more than 300,000 times of electricity
Rated insulation voltage (Ui)
400V
Rated impulse withstand voltage (Uimp)
4KV
Rated open thermal current (Ith)
8A
Use category
AC-15
Rated working voltage (Ue)
AC400V
Rated operating current (le)
2A
Rated limited short-circuit current
1000A
forced disengagement force
≥60N
Forced breakaway distance
≥10mm
Operating frequency
≤ 20 times/minute
Ambient temperature
-20°C~60°C (not freezing)
Environment humidity
Below85%RH
1. The above values are initial values.
2. The contacts of the switch are shared by standard and small loads, but the contacts that operate on a certain load cannot be connected to a load with a smaller capacity for use. Failure to do so may result in damage to the contact surface and reduced contact reliability.
3. Although the switch housing can prevent dust or water from entering, do not use the switch where foreign matter such as powder, water or medicine may enter the keyhole of the switch head, otherwise wear, damage or malfunction of the switch may occur.
4.The conditions for durability are an ambient temperature of 5°C to 35°C and an ambient humidity of 40% to 70%.
DIMENSION
Safety door switch dimension
ACCESSORIES
SAFETY RELAY
Safety Relay LS-A
safety relay for Dadisick Safety Light Curtains
safety relay Ter-A
safety relay for Dadisick Safety Light Curtains
WIRING DIAGRAM
Wiring Diagram Between The Safety Switch and The LS-A Safety Relay
Wiring Diagram Between The Safety Switch and The LS-A Safety Relay
Wiring Diagram Between The Safety Switch and The Ter-A Safety Relay
Wiring Diagram Between The Safety Switch and The Ter-A Safety Relay
SAFETY DOOR HANDLES
DOCUMENTS & DOWNLOADS
CATALOGUE

Safety Interlock Switch Devices OX-D2 & OX-D3 series technical data sheet
3D
OX-D2 & OX-D3.3D-STP