Search This Supplers Products:Safety Light CurtainsMeasuring Light CurtainsSafety Sensor
A:
The output mode (Output Type) of the safety light curtain mainly depends on your equipment control system requirements and safety level design requirements. The following are selection suggestions:
Application Scenario | Recommended output mode | Reason |
---|---|---|
General industrial automation system | PNP / OSSD | Quick response and strong compatibility |
Japanese or old PLC control system | NPN | Matching control input type |
Controlling high power devices (motors/contactors) | Relay output | Dry contacts are safer and can isolate high voltage |
Requires a high safety level (such as PL e or SIL3) | OSSD (dual channel PNP) | Redundancy + self-test, meeting ISO 13849-1 standard |
Use multiple light curtains in series and require intelligent control | OSSD + IO-Link | Remote diagnosis and parameter configuration |
Additional suggestions: